Features:
- HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
- Audible and visual alarm for Occlusion, Equipment failure, Software Exception, Injection finish, Limited finished, Battery running out, improperly installed, abnormal operation etc.
- The syringe pump can be operated separately and compatible with 10ml, 20ml, 30ml, 50/60ml syringe of any brands after correct calibration;
- Preset solution volume to greatly reduce the workload of nurses;
- Three working modes: Rate mode, Time Volume mode, Dosage Weight mode;
- Three levels of occlusion: high, medium and low;
- Purge and Bolus function;
- KVO (keep-vein-open) automatically opens as injection is completed, KVO rate is 0.1-5ml/h (0.1ml/h step);
- Freely Stackable: freely stack one syringe pump onto another to provide multiple solutions, which have a wide range of clinical applications;
- Power Source: 100-240Vac, 50/60Hz; Internal rechargeable Li battery, capacity≥1,800mAh, voltage=11.1V, 4 hours backup time at the rate of 25ml/h (appointed medium rate in IEC60601-2-24) for the new battery charged for 12hours.
- To facilitate the use in some special occasions, the machine’s DC outlet can be an external DC 12V 2A standby power supply.
- One-key operation makes setup easy and simple;
- Syringe plunger grabble detector, operable with one hand in a No-Germ Environment;
- Automatically record the settings of last injection;
- Can store 2000pcs of injection records and it has a drug library;
- OEM is available.
Specifications:
Injection Rate: | 50/60ml Syringe: 0.1ml/h~1500ml/h (0.1ml/h step), |
30ml Syringe: 0.1ml/h~900.0ml/h (0.1ml/h step), | |
20ml Syringe 0.1ml/h—600ml/h (0.1ml/h step), | |
10ml Syringe 0.1ml/h—300ml/h (0.1ml/h step), | |
Rate Accuracy : | Within±3% (after correct calibration). |
Mechanical Accuracy: | Within±2%. |
Maximum Stackable | 8pcs. |
Purge Rate: | 50(60)ml Syringe: 1500ml/h, |
30ml Syringe: 900ml/h, | |
20ml Syringe: 600ml/h, | |
10ml Syringe: 300ml/h, | |
Bolus Rate : | 50(60)ml Syringe: 1200ml/h, |
30ml Syringe: 720ml/h, | |
20ml Syringe: 480ml/h, | |
10ml Syringe: 240ml/h. | |
Volume Limit : | 0.1ml—9999.9ml (0.1ml step). |
Total Injection : | 0.1ml—9999.9ml (0.1ml step). |
Maximum infusion pressure : | 150kPa. |
Occlusion : | High 800mmHg±200mmHg (106.7kPa±26.7kPa), |
Medium 500mmHg±100mmHg (66.7kPa±13.3kPa), | |
Low 300mmHg±100mmHg (40.7kPa±13.3kPa). | |
Audible and Visible Alarms : | Occlusion, Equipment failure, Software Exception, Injection
Finish, Limited finished, Battery running out, Improperly Installed, Abnormal operation etc. |
Power Source: | 100-240Vac, 50/60Hz; Internal rechargeable Li battery, capacity≥1,800mAh, voltage=11.1V, 4 hours backup time at the rate of 25ml/h (appointed medium rate in
IEC60601-2-24) for the new battery charged for 12hours. To facilitate the use in some special occasions, the machine’s DC outlet can be an external DC 12V 2A standby power supply. |
KVO Speed : | 0.1~5ml/h (0.1ml/h step). |
Fuse: | T2AH/250V, 2pcs installed. |
Power Consumption: | 35VA. |
Equipment Classification: | Class I, internal power supply, Type CF. |
IP Classification: | IPX2. |
Operation Environment: | a) Ambient temperature: +5℃~+40℃. |
b) Relative humidity: 20%~90%. | |
c) Atmospheric pressure: 86.0kPa~106.0kPa. | |
Transport & Storage Condition: | a) Ambient temperature: -20℃~+55℃. |
b) Relative Humidity: ≤95%. | |
c) Atmospheric pressure: 50.0kPa~106.0kPa. | |
Syringe : | Compatible with 10ml, 20ml, 30ml, 50/60ml syringe of any brands after correct calibration. |
Syringe maximum value
( under single fault condition): |
1ml. |
Dimension : | 280mm (L) x 210mm (W) x 130mm (H). |
Net Weight: | 2.2Kg. |
Syringe Pump (Single Channel)